Our Proprietary products

GenDx Products

GenDx Products
Sort by
Filters Sort results
Reset Apply
NGS-Turbo®
Complete mono-sample solution for Oxford Nanopore sequencing
NGSgo-ProntoAmp and NGS-ProntoPrep are available as RUO.
Complete solution for Oxford Nanopore sequencing
NGSgo-MX6-1 features six loci in one tube for the amplification of HLA-A, -B, -C, -DRB1, -DQB1 and –DPB1. A ready-to-use PCR mastermix (GenDx-LongMix) is included in the kit. One-Day-Workflow: NGSgo-MX6-1 makes it possible to perform 6-loci HLA typing within 24 hours (10 samples on Illumina MiSeq Nano flow cell). This includes data analysis and report. Compatible with Illumina and PacBio sequencing systems. Available as RUO, CE-marked IVD (IVDR), and Health Canada IVD.
Multiplexed HLA amplification 6 loci
Compatible with Illumina and PacBio sequencing systems.
NGSgo-AmpX v2 is available as RUO, CE-marked IVD (IVDR), and Health Canada IVD. NGSgo-AmpX v3 is available as RUO and CE-marked IVD (IVDR).
Singleplex HLA amplification 11 loci
Library preparation and indexing kit
Library preparation and indexing kit
After sequencing, our designated software, NGSengine-Turbo, provides data analysis within minutes. Analysis is based on renowned NGSengine, with algorithms fully optimized towards ONT data. Reporting is straightforward and provides exactly what you need to communicate your typing results. Available as RUO.
Analysis software for NGS-based typing
After sequencing, our designated software, NGSengine-Turbo, provides data analysis within minutes. Analysis is based on renowned NGSengine, with algorithms fully optimized towards ONT data. Reporting is straightforward and provides exactly what you need to communicate your typing results. Available as RUO.
NGS-Based HLA typing software for analysis data generated with NGS-Turbo assays
8355520-Chimerism monitoring by NGS is the latest development in chimerism surveillance and replaces the less sensitive conventional STR (short tandem repeat) method because of its higher sensitivity (sensitivity of up to 0.1%). GenDx is offering a solution for Chimerism monitoring by NGS, NGStrack® (assay) & TRKengine® (software).
Chimerism monitoring by NGS (assay) Available as RUO
High-sensitivity donor-recipient chimerism monitoring can aid in the diagnosis of leukemia relapse and facilitate timely clinical intervention. Our KMRtype kits can be used to determine presence or absence of genetic markers for chimerism monitoring. By using the qPCR technique, a sensitivity of as low as 0.05% can be reached (20 to 100 fold more sensitive compared to current conventional method using STRs). After genotyping with KMRtype, the KMRtrack kit can be used for monitoring. Both KMRtype and KMRtrack kits are available as RUO and CE-marked IVD.
Genotyping kit to select informative markers for chimerism monitoring Available as RUO & CE-IVD
High-sensitivity donor-recipient chimerism monitoring can aid in the diagnosis of leukemia relapse and facilitate timely clinical intervention. Our KMRtype kits can be used to determine presence or absence of genetic markers for chimerism monitoring. By using the qPCR technique, a sensitivity of as low as 0.05% can be reached (20 to 100 fold more sensitive compared to current conventional method using STRs). After genotyping with KMRtype, the KMRtrack kit can be used for monitoring. Both KMRtype and KMRtrack kits are available as RUO and CE-marked IVD.
Monitoring kit to track chimeric status in time Available as RUO & CE-IVD
When relapse is detected after HLA-mismatched hematopoietic stem cell transplantation (HSCT), it is important to understand whether or not it is characterized by “HLA loss”, i.e. genomic loss of the mismatched HLA, as this has important implications for the appropriate treatment options. The HLA-KMR kit contains 10 markers to detect HLA loss relapse. The 10 genomic markers are all located within HLA genes and integrated in the KMRtype/KMRtrack and KMRengine workflow. Available as RUO.
HLA loss detection assays Available as RUO
KMRassay qPCR Buffer & Enzyme contains the necessary buffer and enzyme for the performance of KMRtype and KMRtrack. Available as RUO and CE-marked IVD.
qPCR Buffer & Enzyme
KMRassay Reference Assay 901 contains the necessary genetic reference for the performance of KMRtype and KMRtrack. This assay targets a housekeeping gene outside the HLA region and has been designed to give a positive result for all human DNA. Available as RUO and CE-marked IVD.
Chimerism monitoring by NGS is the latest development in post-transplantation surveillance and replaces the less sensitive conventional STR (short tandem repeat) method because of its higher sensitivity (2-10 times more sensitive). GenDx is offering a solution for Chimerism monitoring by NGS, NGStrack® (assay) & TRKengine® (software). NGStrack results can be visualized with TRKengine, our in-house developed software, based on the best features of our renowned NGSengine® and KMRengine® software packages that have been perfected for over a decade. NGStrack and TRKengine are available as RUO.
Chimerism monitoring by NGS (software)
KMRengine is our highly intuitive software for the chimerism monitoring workflow. KMRengine guides you through the entire workflow, from genotyping to monitoring, from the first time point to the most recent time point of monitoring. Available as RUO and CE-marked IVD.
Analysis software for qPCR-based chimerism monitoring (KMRtype, KMRtrack and HLA-KMR assays)
Allele-level KIR typing by NGS
en_GB
Scroll to Top